Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.358
Filtrar
1.
Medicine (Baltimore) ; 103(14): e37723, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579029

RESUMO

INTRODUCTION: Transseptal punctures (TSPs) are widely used in left atrium and left ventricle surgery. Accidental puncture of the puncture needle into the aorta is a rare complication that is rarely reported but has serious consequences. The appropriate management of this complication remains unclear. PATIENT CONCERNS: This report describes a case of a male with the chief complaint: paroxysmal palpitation for 1 year, aggravated for 1 month. DIAGNOSIS: The electrophysiological diagnosis was atrioventricular reentrant tachycardia caused by left-side bypass. INTERVENTIONS: Radiofrequency ablation of the heart was a necessary treatment and a TSP operation was needed, in which a puncture was mistakenly believed to have entered the aorta, a series of measures were taken urgently. Although the surgical procedure in this case was a false alarm, we still initiated a series of emergency plans. Emergency measures to address the complications were effectively implemented, and the emergency measures were promptly terminated after it was clear that complications had been misjudged. OUTCOMES: At last, it was confirmed that the angiogram was a pulmonary artery image, not an aorta image. Then the atrial septal puncture operation was successfully completed, and under the guidance of the Carto system, the ablation was successfully completed. Postoperative fluoroscopy showed no complications, such as pericardial effusion. After 2 years of follow-up, there was no reoccurrence of tachycardia, and there were no complications. It is crucial that emergency procedures are terminated in a timely manner after a clear miscarriage of performance. Although accidental puncture into the aorta is urgent and serious, performing a blockage or even thoracotomy in an emergency if complications are not clearly confirmed can cause further damage to the patient and would be a definitively wrong strategy. CONCLUSION: Strict and standardized TSP operations can avoid complications. Correct judgment of the authenticity of complications is crucial, and remedial measures that may cause further damage should not be blindly adopted. The retention of the aortic guide wire can provide convenient access for further differential diagnosis and remedial treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Comunicação Interatrial , Ablação por Radiofrequência , Humanos , Masculino , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Retrospectivos , Punções/efeitos adversos , Punções/métodos , Aorta/cirurgia , Comunicação Interatrial/cirurgia , Fibrilação Atrial/cirurgia
3.
Head Neck ; 46(4): 973-978, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38278774

RESUMO

Tracheoesophageal puncture (TEP) performed during total laryngectomy in the primary treatment of laryngeal cancer is the standard method for voice restoration. Following adjuvant radiotherapy, the TEP site can experience complications resulting in a tracheoesophageal fistula (TEF) with chronic leakage making oral alimentation unsafe due to aspiration. Here, we describe a technique using chimeric ulnar artery perforator forearm free flaps (UAPFF) in the reconstruction of these complex deformities. Four patients underwent chimeric UAPFF reconstruction of TEP site TEFs following primary TL with TEP and adjuvant radiotherapy. No flap failures or surgical complications occurred. Average time from end of radiotherapy to persistent TEF was 66 months (range 4-190 months). All patients had resolution in their TEF with average time to total oral diet achievement of 22 days (14-42 days). Chimeric UAPFF reconstruction is a safe and effective method to reconstruct recalcitrant TEP site TEFs.


Assuntos
Neoplasias Laríngeas , Laringe Artificial , Fístula Traqueoesofágica , Humanos , Fístula Traqueoesofágica/etiologia , Fístula Traqueoesofágica/cirurgia , Antebraço/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Laringectomia/efeitos adversos , Laringectomia/métodos , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/cirurgia , Punções/métodos , Traqueia/cirurgia
4.
Pacing Clin Electrophysiol ; 47(2): 330-335, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38240379

RESUMO

OBJECTIVE: This study aims to investigate the anatomical variations in femoral vasculature and evaluate the clinical value of ultrasound-guided femoral vein puncture in catheter ablation procedures. METHODS: In this retrospective analysis conducted from January 2023 to March 2023, we examined data from patients who underwent catheter ablation with ultrasound-guided femoral venipuncture. We evaluated the anatomy of the femoral vasculature at both high and low inguinal levels. Based on the relationship between the femoral vein and artery, we classified the anatomy into four types: Type I (vein parallel to artery without overlap), Type II (vein medial to artery with lumen overlap ≤50%), Type III (vein posterior to artery with lumen overlap > 50%), and Type IV (vein lateral to artery). Additionally, we assessed procedure-related vascular complications that required interventions or prolonged hospital stays. RESULTS: A total of 254 patients were included in this study. At the upper inguinal level, most cases (92.5%) exhibited Type II, followed by Type I (6.5%), while Type III (0.6%) and IV (0.4%) were less common. At the lower inguinal level, Type II accounted for 70.7%, there was a significantly higher proportion of Type III (23.4%) and Type IV (5.9%). The overall complication rate was 0.4%, no pseudoaneurysm or hematoma was observed in our study. CONCLUSION: Our study revealed significant anatomical variations in the relationship between the femoral vein and femoral artery. Ultrasound-guided femoral venipuncture significantly reduced vascular complication rate, making it a valuable tool for guiding puncture procedures.


Assuntos
Ablação por Cateter , Flebotomia , Humanos , Veia Femoral/diagnóstico por imagem , Veia Femoral/cirurgia , Estudos Retrospectivos , Arritmias Cardíacas , Punções/métodos , Artéria Femoral/cirurgia , Artéria Femoral/diagnóstico por imagem , Ultrassonografia de Intervenção
5.
Pacing Clin Electrophysiol ; 47(3): 448-454, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38291877

RESUMO

BACKGROUND: Application of electrocautery to a J-wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique. METHODS: Two hundred consecutive patients were randomized in a 1:1 fashion to either the ICE-guided electrified J-wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, "coag" mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time. RESULTS: All patients complete the procedure safely. The electrified J-wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra-atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J-wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra-atrial shunt (4.3% vs. 6%, p = .654) during the 3-month's follow up. CONCLUSION: Using an electrified J-wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non-fluoroscopy AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Punções/métodos , Ablação por Cateter/métodos , Ecocardiografia , Resultado do Tratamento
6.
Head Neck ; 46(2): 435-438, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37989711

RESUMO

In Video S1, a new surgical technique for hybrid primary tracheoesophageal (TE) puncture in stapler-assisted total laryngectomy is shown. The video describes the surgical steps of the procedure and illustrates some tips and tricks. The procedure incorporates an upper mini-pharyngotomy to enable retrograde placement of the voice prosthesis (VP), eliminating the need for rigid esophagoscopy. This has made it possible to exploit, without additional risks, the potential of the stapler combined with primary TE puncture and VP placement. In our experience, this hybrid procedure in stapler-assisted total laryngectomy is not related to adverse events such as pharyngocutaneous fistula (PCF), hypertonicity, and functional complications. Therefore, it can be considered a valid technique that allows for easy insertion of a primary voice prosthesis also in case of mechanical sutures.


Assuntos
Neoplasias Laríngeas , Laringe Artificial , Humanos , Laringectomia/métodos , Esôfago/cirurgia , Traqueia/cirurgia , Neoplasias Laríngeas/cirurgia , Neoplasias Laríngeas/etiologia , Punções/métodos
7.
Rev Paul Pediatr ; 42: e2023089, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38088681

RESUMO

OBJECTIVE: To evaluate the focus of pediatricians' gaze during the heel prick of neonates. METHODS: Prospective study in which pediatricians wearing eye tracker glasses evaluated neonatal pain before/after a heel prtick. Pediatricians scored the pain they perceived in the neonate in a verbal analogue numerical scale (0=no pain; 10=maximum pain). The outcomes measured were number and time of visual fixations in upper face, lower face, and hands, in two 10-second periods, before (pre) and after the puncture (post). These outcomes were compared between the periods, and according to pediatricians' pain perception: absent/mild (score: 0-5) and moderate/intense (score: 6-10). RESULTS: 24 pediatricians (31 years old, 92% female) evaluated 24 neonates. The median score attributed to neonatal pain during the heel prick was 7.0 (Interquartile range: 5-8). Compared to pre-, in the post-periods, more pediatricians fixed their gaze on the lower face (63 vs. 92%; p=0.036) and the number of visual fixations was greater on the lower face (2.0 vs. 5.0; p=0.018). There was no difference in the number and time of visual fixations according to the intensity of pain. CONCLUSIONS: At bedside, pediatricians change their focus of attention on the neonatal face after a painful procedure, focusing mainly on the lower part of the face.


Assuntos
Calcanhar , Punções , Recém-Nascido , Humanos , Feminino , Adulto , Masculino , Medição da Dor/métodos , Estudos Prospectivos , Punções/efeitos adversos , Punções/métodos , Dor/diagnóstico , Dor/etiologia
8.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38011331

RESUMO

AIMS: This study was performed to compare the usability, efficiency, and safety of a modified angioplasty guidewire-assisted transseptal puncture (TSP) technique vs. the conventional approach in facilitating access into the left atrium during left atrial appendage occlusion (LAAO) procedures for the treatment of atrial fibrillation. METHODS AND RESULTS: The ADVANCE-LAAO trial (Angioplasty Guidewire-Assisted vs. Conventional Transseptal Puncture for Left Atrial Appendage Occlusion) was an investigator-initiated, prospective, multicentre, randomized controlled trial (NCT05125159). Patients with atrial fibrillation who underwent LAAO were prospectively enrolled from four centres and randomly assigned to an angioplasty guidewire-assisted TSP group (n = 131) or to a conventional Brockenbrough needle TSP group (n = 132). The primary endpoint was the one-time success rate of TSP. We also analysed the TSP procedure time, failure rate of the assigned TSP type, radiation dose, contrast dose, and procedural complications in both groups. All patients in the guidewire-assisted group underwent successful TSP, whereas five in the standard conventional group switched to the guidewire-assisted approach. The guidewire-assisted puncture improved the one-time success rate (92.4 vs. 77.3%, P = 0.001), shortened the TSP procedure time (109.2 ± 48.2 vs. 120.5 ± 57.6 s, P = 0.023), and tended to have a higher rate of good coaxial orientation of the sheath with the left atrial appendage during the LAAO procedure (66.4 vs. 54.5%, P = 0.059). No TSP-related complications occurred in the guidewire-assisted TSP group, whereas two complications occurred in the conventional TSP group. There was no significant difference in the failure rate of the assigned TSP type, the total procedure time, the total radiation dose, the rate of successful LAAO implantation, or the procedural complication rate between the two groups (all P > 0.05). CONCLUSION: This study confirmed that angioplasty guidewire-assisted puncture can effectively improve the success rate of TSP during LAAO procedures. This novel technique has high potential for application in interventional therapies requiring TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Angioplastia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Punções/métodos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 102(7): 1331-1340, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37855202

RESUMO

BACKGROUND: The presented study investigates the application of bi-arterial 3D printed models to guide transseptal puncture (TSP) in left atrial appendage closure (LAAC). AIMS: The objectives are to (1) test the feasibility of 3D printing (3DP) for TSP guidance, (2) analyse the distribution of the optimal TSP locations, and (3) define a CT-derived 2D parameter suitable for predicting the optimal TSP locations. METHODS: Preprocedural planning included multiplanar CT reconstruction, 3D segmentation, and 3DP. TSP was preprocedurally simulated in vitro at six defined sites. Based on the position of the sheath, TSP sites were classified as optimal, suboptimal, or nonoptimal. The aim was to target the TSP in the recommended position during the procedure. Procedure progress was assessed post hoc by the operator. RESULTS: Of 68 screened patients, 60 patients in five centers (mean age of 74.68 ± 7.64 years, 71.66% males) were prospectively analyzed (3DP failed in one case, and seven patients did not finally undergo the procedure). In 55 patients (91.66%), TSP was performed in the optimal location as recommended by the 3DP. The optimal locations for TSP were postero-inferior in 45.3%, mid-inferior in 45.3%, and antero-inferior in 37.7%, with a mean number of optimal segments of 1.34 ± 0.51 per patient. When the optimal TSP location was achieved, the procedure was considered difficult in only two (3.6%) patients (but in both due to complicated LAA anatomy). Comparing anterior versus posterior TSP in 2D CCT, two parameters differed significantly: (1) the angle supplementary to the LAA ostium and the interatrial septum angle (160.83° ± 9.42° vs. 146.49° ± 8.67°; p = 0.001), and (2) the angle between the LAA ostium and the mitral annulus (95.02° ± 3.73° vs. 107.38° ± 6.76°; p < 0.001), both in the sagittal plane. CONCLUSIONS: In vitro TSP simulation accurately determined the optimal TSP locations for LAAC and facilitated the procedure. More than one-third of the optimal TSP sites were anterior.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Punções/métodos
10.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 35(10): 1099-1100, 2023 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-37873717

RESUMO

Deep venipuncture catheterization is a routine and basic operation in the treatment of critically ill patients, and it is the most effective way to quickly correct the shock. Clinical B-ultrasound guided deep vein catheters can improve the success rate of puncture, but in the process of operation, the short axis needs to be replaced by the long axis. In the replacement process, the stability of the novice is insufficient, the positioning is difficult, and the operation time is too long. If only short axis puncture is used, it is impossible to know whether the current position of the puncture needle, and the puncture may be too deep and stray into the artery. The accuracy of the 45 degree angle of the injection point requires a very experienced operator. In view of the above shortcomings, doctors in the department of critical care medicine of Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a B-ultrasound puncture equipment, which has obtained the National Invention Patent of China (ZL 2016 1 0571557.X). The device is composed of B-ultrasound probe fixing frame, sliding scale plate, simulation slide rule, puncture needle, sliding device. By sliding device the angle of the pinhole channel, it is conducive to the accurate positioning of the puncture target, optimizing the operation procedure, improving the puncture speed and accuracy, effectively reducing the occurrence of puncture complications, ensuring patient safety, reducing unnecessary waste of human and material resources. It can reduce the workload of medical staff and is worthy of clinical practice.


Assuntos
Cateterismo Venoso Central , Humanos , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Ultrassonografia de Intervenção/métodos , Ultrassonografia , Punções/métodos , Agulhas
11.
Crit Care ; 27(1): 379, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37777778

RESUMO

BACKGROUND: Out-of-plane (OOP) approach is frequently used for ultrasound-guided insertion of central venous catheter (CVC) owing to its simplicity but does not avoid mechanical complication. In-plane (IP) approach might improve safety of insertion; however, it is less easy to master. We assessed, a homemade needle guide device aimed to improve CVC insertion using IP approach. METHOD: We evaluated in a randomized simulation trial, the impact of a homemade needle guide on internal jugular, subclavian and femoral vein puncture, using three approaches: out-of-plane free hand (OOP-FH), in-plane free hand (IP-FH), and in-plane needle guided (IP-NG). Success at first pass, the number of needle redirections and arterial punctures was recorded. Time elapsed (i) from skin contact to first skin puncture, (ii) from skin puncture to successful venous puncture and (iii) from skin contact to venous return were measured. RESULTS: Thirty operators performed 270 punctures. IP-NG approach resulted in high success rate at first pass (jugular: 80%, subclavian: 95% and femoral: 100%) which was higher than success rate observed with OOP-FH and IP-FH regardless of the site (p = .01). Compared to IP-FH and OOP-FH, the IP-NG approach decreased the number of needle redirections at each site (p = .009) and arterial punctures (p = .001). Compared to IP-FH, the IP-NG approach decreased the total procedure duration for puncture at each site. CONCLUSION: In this simulation study, IP approach using a homemade needle guide for ultrasound-guided central vein puncture improved success rate at first pass, reduced the number of punctures/redirections and shortened the procedure duration compared to OOP and IP free-hand approaches.


Assuntos
Cateterismo Venoso Central , Humanos , Cateterismo Venoso Central/métodos , Veias Jugulares/diagnóstico por imagem , Punções/métodos , Ultrassonografia , Ultrassonografia de Intervenção/métodos
12.
Int Urol Nephrol ; 55(10): 2373-2379, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37393384

RESUMO

PURPOSE: The aims of this study were to analyze the clinical outcomes of treating duplex system ureteroceles with early endoscopic puncture decompression and to identify the risk factors related to outcomes to help guide future work. MATERIALS AND METHODS: We retrospectively reviewed the clinical records of patients with ureteroceles with duplex kidney that were treated with early endoscopic puncture decompression. Charts were reviewed for demographics, preoperative imaging, surgical indications, and follow-up data. Recurrent febrile urinary tract infections (fUTIs), de novo vesicoureteral reflux (VUR), persistent high-grade VUR, unrelieved hydroureteronephrosis, and the need for further intervention were considered unfavorable outcomes. Gender, age at surgery, BMI, antenatal diagnosis, fUTIs, bladder outlet obstruction (BOO), type of ureterocele, ipsilateral VUR diagnosed before surgery, simultaneously upper-pole moiety (UM) and lower-pole moiety (LM) obstruction, the width of ureter affiliated to UM, and maximum diameter of ureterocele were all considered potential risk factors. A binary logistic regression model was used to identify the risk factors of unfavorable outcomes. RESULTS: A total of 36 patients with ureteroceles related to duplex kidney underwent endoscopic holmium laser puncture from 2015 to 2023 at our institution. After a median follow-up of 21.6 months, unfavorable outcomes developed in 17 patients (47.2%). Three patients underwent ipsilateral common-sheath ureter reimplantation and one patient underwent laparoscopic ipsilateral upper to lower ureteroureterostomy combined with recipient ureter reimplantation. Three patients underwent laparoscopic upper-pole nephrectomy. Fifteen patients suffered from recurrent UTIs were treated with oral antibiotics and eight of them were diagnosed de novo VUR according to voiding cystourethrography (VCUG). In univariate analysis, patients with simultaneously UM and LM obstruction (P = 0.003), fUTIs before surgery (P = 0.044), and ectopic ureterocele (P = 0.031) were more likely to have unfavorable outcomes. Binary logistic regression analysis showed that ectopic ureterocele (OR = 10.793, 95% CI 1.248-93.312, P = 0.031) and simultaneously UM and LM obstruction (OR = 8.304, 95% CI 1.311-52.589, P = 0.025) were identified as independent factors for unfavorable outcomes. CONCLUSIONS: Our study suggested that early endoscopic puncture decompression is not a preferred but an available treatment option to release BOO or to cure refractory UTIs. It was easier to fail if the ureterocele was ectopic or simultaneously UM and LM obstruction existed. Gender, age at surgery, BMI, antenatal diagnosis, fUTIs, bladder outlet obstruction (BOO), ipsilateral VUR diagnosed before surgery, the width of ureter affiliated to UM, and maximum diameter of ureterocele were not significantly related to the success rate of early endoscopic punctures.


Assuntos
Nefropatias , Laparoscopia , Ureterocele , Obstrução do Colo da Bexiga Urinária , Infecções Urinárias , Refluxo Vesicoureteral , Criança , Humanos , Feminino , Gravidez , Lactente , Ureterocele/complicações , Ureterocele/cirurgia , Ureterocele/diagnóstico , Estudos Retrospectivos , Obstrução do Colo da Bexiga Urinária/complicações , Nefropatias/etiologia , Rim , Refluxo Vesicoureteral/complicações , Refluxo Vesicoureteral/cirurgia , Infecções Urinárias/etiologia , Fatores de Risco , Punções/métodos , Laparoscopia/efeitos adversos , Descompressão/efeitos adversos , Resultado do Tratamento
13.
Front Endocrinol (Lausanne) ; 14: 1198564, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37448466

RESUMO

Background: Intracerebral hemorrhage (ICH) is the deadliest subtype of stroke, with a 30-day case fatality rate of approximately 40%. Timely and accurate treatment is essential to facilitate recovery. The introduction of stereotactic instruments and navigation systems has greatly improved the accuracy of surgical treatment. In this study, we explored the application and effects of a three-dimensional (3D) laser combined with C-arm computed tomography (CT) on ICH puncture. Materials and methods: According to the principle of randomness, 118 patients with ICH were divided into control and experimental groups. The control group was treated with CT-guided puncture, and the experimental group was treated with 3D laser combined with C-arm CT puncture. The hematoma clearance rates at 3, 5, and 7 days after surgery and the prognosis at 1, 3, and 6 months after surgery were compared between the two groups. Results: The hematoma clearance rates of the group using 3D laser combined with C-arm CT at 3, 5, and 7 days after surgery were significantly higher than those of the control group, and the difference was statistically significant (p < 0.05). One month postoperatively, the daily living ability (ADL) grading and recovery of the patients in the test group was significantly better than those of the control group (p < 0.05), but there was no statistically significant difference in ADL 3 and 6 months after surgery (p > 0.05). Conclusion: 3D laser combined with C-arm CT puncture has the advantages of real-time guidance, accurate positioning, and simple operation. It is an effective minimally invasive surgical method that is easy to master.


Assuntos
Hemorragia Cerebral , Drenagem , Humanos , Drenagem/métodos , Resultado do Tratamento , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/cirurgia , Punções/métodos , Tomografia Computadorizada por Raios X , Hematoma/diagnóstico por imagem , Hematoma/cirurgia
14.
Int J Clin Pract ; 2023: 5534451, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37457808

RESUMO

Objective: This study compared the effect of ultrasound-guided subclavian vein puncture with traditional blind puncture and the double-screen control method by evaluating the one-time puncture success and total success rates, the completion time for puncture and catheterization, and short-term complications. Methods: From January 2020 to January 2021, 72 patients with right subclavian venipuncture catheterization were collected, 12 of whom were excluded (including 3 cases of pneumothorax, 2 cases of hemothorax, 1 case of difficult positioning of thoracic deformity, 1 case of severe drug eruption, 3 cases of clavicle fracture, and 1 case of severe coagulation dysfunction). The remaining 60 cases were randomly divided into the traditional group (n = 30) and the improved group (n = 30). We record two sets of ultrasound localization time, puncture time, one-time puncture power, total puncture success rate, and short-term (24-hour) complications. Results: Compared with the traditional group, the ultrasound positioning time and puncture time in the improved group were significantly reduced and the puncture success rate was higher. There were no complications, such as incorrect arterial puncture and the occurrence of pneumothorax, in either group. Conclusion: The improved ultrasound-guided subclavian vein catheterization technique can greatly reduce the catheterization time and improve the success rate of puncture and catheterization. It can also reduce the occurrence of complications and damage to adjacent tissues. The operation is simple, fast, and easy to master, and it has a high popularization clinical value.


Assuntos
Cateterismo Venoso Central , Pneumotórax , Humanos , Cateterismo Venoso Central/efeitos adversos , Flebotomia/efeitos adversos , Pneumotórax/etiologia , Punções/efeitos adversos , Punções/métodos , Veia Subclávia/diagnóstico por imagem , Ultrassonografia de Intervenção/efeitos adversos
15.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37378419

RESUMO

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Assuntos
Veia Axilar , Venostomia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Veia Axilar/cirurgia , Venostomia/métodos , Veia Subclávia , Punções/métodos , Coração
16.
Anatol J Cardiol ; 27(9): 534-538, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37288868

RESUMO

BACKGROUND: Although several procedures of subclavian venipuncture have been reported, no standard method has been established yet. The purpose of this study was to investigate some more accurate and improved blind puncture tips. METHODS: A prospective study was conducted on patients who underwent cardiac radio-frequency ablation with the blind technique of subclavian venipuncture from August 2018 to June 2022. All patients were randomly assigned to an intrathoracic approach group or extrathoracic approach group. Each group of patients followed their own specific puncture scheme and tips. RESULTS: About 371 punctures were included. Blind subclavian venipunctures were performed with 98.9% technical success and without complications in all patients. The over-all success rate with an intrathoracic and extrathoracic approach was equivalent (96.7% vs. 98.3%, P =.23). The intrathoracic group showed a higher first-pass success compared with the extrathoracic group (91.9% vs. 80.2%, P = 0.003, respectively). CONCLUSION: We localized the landmark/reference and skin puncture site of an intrathoracic and extrathoracic subclavian venipuncture individually and quantitatively. These experiences make blind techniques more accurate and faster.


Assuntos
Punções , Veia Subclávia , Humanos , Veia Subclávia/diagnóstico por imagem , Veia Subclávia/cirurgia , Estudos Prospectivos , Punções/métodos , Flebotomia/métodos
17.
Neurosurg Rev ; 46(1): 104, 2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37145343

RESUMO

Basal ganglia hemorrhage, which is characterized by excessive incapacity charge and high mortality rates, is surgically treated by minimally invasive hematoma puncture and drainage. We aimed at determining the efficacy of laser-guided minimally invasive hematoma puncture and drainage for treatment of basal ganglia hemorrhage. A total of 61 patients with hypertensive basal ganglia hemorrhage were recruited at the Binzhou Medical University Hospital, between October 2019 and January 2021, and their clinical information retrospectively analyzed. Based on the surgical approach used, patients were assigned into either laser navigation or small bone window groups depending on the surgical approach. Then, we compared the operation times, intraoperative blood loss, clinic stay, Glasgow Outcome Score (GOS) rating at 30 days, Barthel index (BI) rating at 6 months, postoperative pneumonia incidences, and intracranial contamination complications between groups. Intraoperative blood loss, operation time, and sanatorium were significantly low in laser navigation group, relative to the small bone window group. At the same time, there were no significant differences between the groups with regard to postoperative hematoma volume, lung contamination, cerebrospinal fluid (CSF) leak, and intracranial contamination, as well as the 6-month BI and 30-day GOS rating. There were no deaths in either group. Compared with the traditional small bone window surgery, laser-guided puncture and drainage is a low-cost, accurate, and safe method for the treatment of basal ganglia hemorrhage, which is suitable for promotion in developing countries and economically underdeveloped areas.


Assuntos
Hemorragia dos Gânglios da Base , Perda Sanguínea Cirúrgica , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Hemorragia dos Gânglios da Base/cirurgia , Punções/métodos , Tecnologia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Hematoma/cirurgia , Gânglios da Base/cirurgia , Hemorragia Cerebral/cirurgia
18.
IEEE Trans Biomed Eng ; 70(10): 3003-3014, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37220031

RESUMO

OBJECTIVE: Transseptal puncture (TP) is the technique used to access the left atrium of the heart from the right atrium during cardiac catheterization procedures. Through repetition, electrophysiologists and interventional cardiologists experienced in TP develop manual skills to navigate the transseptal catheter assembly to their target on the fossa ovalis (FO). Cardiology fellows and cardiologists that are new to TP currently train on patients to develop this skill, resulting in increased risk of complications. The goal of this work was to create low-risk training opportunities for new TP operators. METHODS: We developed a Soft Active Transseptal Puncture Simulator (SATPS), designed to match the dynamics, static response, and visualization of the heart during TP. The SATPS includes three subsystems: (i) A soft robotic right atrium with pneumatic actuators mimics the dynamics of a beating heart. (ii) A fossa ovalis insert simulates cardiac tissue properties. (iii) A simulated intracardiac echocardiography environment provides live visual feedback. Subsystem performance was verified with benchtop tests. Face and content validity were evaluated by experienced clinicians. RESULTS: Subsystems accurately represented atrial volume displacement, tenting and puncture force, and FO deformation. Passive and active actuation states were deemed suitable for simulating different cardiac conditions. Participants rated the SATPS as realistic and useful for training cardiology fellows in TP. CONCLUSION: The SATPS can help improve catheterization skills of novice TP operators. SIGNIFICANCE: The SATPS could provide novice TP operators the opportunity to improve their TP skills before operating on a patient for the first time, reducing the likelihood of complications.


Assuntos
Ablação por Cateter , Cardiopatias , Robótica , Humanos , Átrios do Coração , Cateterismo Cardíaco/métodos , Punções/métodos , Ablação por Cateter/métodos
19.
Acad Radiol ; 30(12): 3047-3055, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37117142

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the targeting accuracy of laser-guided punctures in combination with an aiming device for computed tomography (CT) interventions during in vitro experiments. MATERIALS AND METHODS: A total of 600 CT-guided punctures were performed using a laser target system, half of them with the additional help of an aiming device. Conically shaped targets in a plexiglass phantom were punctured. The planning CT data sets were acquired with 1.25, 2.5 and 5 mm slice thickness. Needle placement accuracy, as well as procedural time, was assessed. The Euclidean (ED) and normal distances (ND) were calculated at the target point. RESULTS: Using the aiming device, the accomplished mean ND at the target for the 1.25, 2.5 and 5 mm slice thickness was 1.76 mm (SD ± 0.92), 2.09 mm (SD ± 1.06) and 1.93 mm (SD ± 1.38), respectively. Without aiming device, the corresponding results were 2.55 mm (SD ± 1.42), 2.7 mm (SD ± 1.43) and 2.31 mm (SD ± 1.64). At a slice thickness of 1.25 mm and 2.5 mm, punctures with the aiming device were significantly more accurate for both the ED and ND as compared to the punctures without aiming device (p < 0.001). The mean time required to complete the procedure, including image acquisition, trajectory planning, the placement of 10 needles, and the control-CT scan was 24.8 min without and 29.8 min with the aiming device. CONCLUSION: The additional use of the aiming device in combination with the commercially available laser guidance system significantly increased the level of accuracy during this in vitro experiment compared to freehand passes.


Assuntos
Agulhas , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Punções/métodos , Imagens de Fantasmas , Lasers
20.
Lab Anim ; 57(6): 642-649, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37077144

RESUMO

The objective of this study was to investigate the feasibility of external jugular vein catheterization through an ear vein in piglets. Forty-six sevoflurane-midazolam anaesthetized piglets were included. External jugular vein catheterization was conducted through the ear vein using the Seldinger technique. Part 1 (n = 27): optimal puncture site was based on the deltoid tuberosity as a landmark to reach the external jugular vein. The final position of the catheter was verified in 25 piglets using computer tomography. Catheterization time was recorded and patency of the catheter assessed by repeated blood sampling for up to 4 h. Part 2 (n = 19): ear vein catheterization was without taking into account any landmarks. Functionality for blood sampling was evaluated as described in part 1. Catheter advancement was possible in 25/27 and 18/19 piglets in parts 1 and 2, respectively. Median (range) time required for successful catheterization was 1.95 (1-10) min (n = 38). The deltoid tuberosity was a good landmark to reach the external jugular vein. But blood sampling was also possible through catheters ending slightly cranial to the external jugular vein. Despite successful catheter advancement, blood sampling was not possible from one catheter in each part of the study (total: two piglets). One of these catheters presented luminal damage, while the other one presented as normal after being removed from the animal. Summarizing, central vein catheterization through the ear vein was feasible in 93.5% and repeated blood sampling was possible in 89.1% of the piglets (n = 46).


Assuntos
Cateterismo Venoso Central , Veias Jugulares , Animais , Suínos , Veias Jugulares/cirurgia , Cateterismo Venoso Central/métodos , Punções/métodos , Flebotomia , Coleta de Amostras Sanguíneas/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...